Two-color pyrometer – QKTRD 4485

Measuring ranges from 700 °C to 2500 °C

1. 700 – 1600 °C
2. 800 – 2500 °C

Special measuring ranges upon request

Description

Performance, precision and reliability – you can count on MAURER pyrometers. The compact and easy to use design, as well as a large selection of matching accessories, enables you to quickly integrate the pyrometer into your surroundings.

The most important features and characteristics at a glance:

  • Spectral range: 0,85 – 1,1 µm
  • Short responsetime of 1 ms, with dynamic adjustment
  • Emissivity slope from 0,8 – 1,2, adjustable directly at the pyrometer or via interface
  • Green target light (LED) that is exactly identical to the actual measuring spot in position and size
  • With fiber optic cable and optic system for exact focusing even in narrow spaces
  • Use with either digital and analogue output
  • 1 limit output (open collector)
  • Operating voltage 24 V DC
  • Free software (IR-LOG) for parameter setting, data recording and storage

Scope of Applications
Processing of steel, iron, non-ferrous metal and wires, ceramics, glass tub, glass arching, as well as hardening, rolling, soldering, forging, welding, transforming, induction heating, vacuum furnace, etc.

Fiber optic cables

  • Quartz fiber optic cable in metal hose
  • Ambient temperature max. 150 °C
  • Bending radius min. 100 mm
  • Both sides with FSMA-plug for connecting the pyrometer and the optic system
  • Custom-tailored lengths and other fibers available upon request

Configurations

  • Special objectives and measuring ranges upon request
Spectral range 0,85 – 1,1 μm
Target marking Target light
Response time 1 msec, with dynamic adjustment
Measurement uncertainty 0,5 % ± 1 °C (ε = 1, Tu = 23°C, T 95 = 1s)
Temperature dependence 0,01 % / °C
Reproducibility 0,1 %
Emissivity 0,8 – 1,2, adjustable directly at the pyrometer or via interface
Resolution < 0,1 % at the analogue output < 0,1 °C at the interface
Analogue output 0 – 20 mA bzw. 4 – 20 mA (Load max. 500 Ω)
Limit output 1x 24 V 100 mA (open coll.)
Interface RS 232 ± 50 V isolated or RS 485 ± 70 V isolated
Device connection 8-pol. plug connector for RS485
7-pol. plug connector for RS232
Operating temperature 0 – 60 °C, Optik 150 °C
Storage temperature -10 °C – 70 °C
Permissible humidity 35 – 85 % RF (non condensing)
Supply voltage 24 V DC ± 10 %
Power consumption < 100 mA
IP code IP65
Dimensions (LxHxW) / Weight 30 x 65 x 80 mm / 0,19 kg
Other Maximum memory, peak value memory double, adjustable time and threshold value, erasing after time, external contact, by software, after every measuring object

Fix-Focus

Fix-Fokus Optik Legend</strong
L Length of opics
C Distance from optics edge
M Measurement spot size
Optics C [mm] L [mm] Fiber [µm] M [mm]
VL 50-M12 50 38 200 0,7
400 1,4
600 2,0
VL 100-M12 100 40 200 1,0
400 2,0
600 3,0
VL 150-M12 150 38 200 1,4
400 2,7
600 4,0
VL 200-M12 200 38 200 2,0
400 4,0
600 6,0

Vario-Focus

Vario-Fokus Optik Legende</strong
L Length of optics
C Distance from optics edge
M Measurement spot size
Optics Cmin [mm] Cmax [mm] L [mm] Faser [µm] R Ratio
VL-VA N 65 160 46 – 56 200 138
400 69
600 46
VL-VA T 100 5000 46 – 56 200 150
400 75
600 50

KTRD44xx for wave guide optics

KTRD44xx for wave guide optics

Optics for wave guides

optics for wave guides

Go to Top