Two-color pyrometer – QKTRD 1475

Measuring ranges from 300 °C to 1700 °C

1. 300 – 1000 °C
2. 350 – 1300 °C
3. 400 – 1400 °C
4. 500 – 1700 °C

Special measuring ranges upon request

Description

Performance, precision and reliability – you can count on MAURER pyrometers. Benefit from maximum adaptability by choosing the right optics, accessories and the appropriate interface. Thus our pyrometer fits perfectly into existing systems.

The most important features and characteristics at a glance:

  • Spectral range: 1,4 – 1,75 μm and 1,6 – 1,75 μm
  • Short response time from less than 1 ms
  • Emissivity slope from 0,8 – 1,2, adjustable directly at the pyrometer or via interface
  • Green target light (LED) that is exactly identical to the actual measuring spot in position and size
  • With fiber optic cable and optic system for exact focusing even in narrow spaces
  • Use with either digital and analogue output
  • 1 limit output (open collector)
  • Operating voltage 24 V DC
  • Free software (IR-LOG) for parameter setting, data recording and storage

Scope of Applications
Processing of steel, iron, non-ferrous metal and wires, as well as rolling, soldering, annealing, hardening, forging, transforming, induction heating, etc.

Fiber optic cables

  • Quartz fiber optic cable in metal hose
  • Ambient temperature  max. 150 °C
  • Minimum bending radius = 200 x fiber thickness
  • Both sides with FSMA-plug for connecting the pyrometer and the optic system
  • Custom-tailored lengths and other fibers available upon request.

Configurations

  • Built-in digital display on the backside of the pyrometer
Spectral range 1,4 – 1,7 μm and 1,6 – 1,75 μm
Target marking Target light
Response time < 1 ms, with dynamic adjustment
Measurement uncertainty 0,5 % ± 1 °C (ε = 1, Tu = 23°C, T 95 = 1s)
Temperature dependence 0,01 % / °C
Reproducibility 0,1 %
Emissivity 100 – 10 %, adjustable directly at the pyrometer or via interface
Resolution < 0,1 % at the analogue output < 0,1 °C at the interface
Analogue output 0 – 20 mA bzw. 4 – 20 mA (Load max. 500 Ω)
Limit output 1x 24 V 100 mA (open coll.)
Interface RS 232 ± 50 V isolated or RS 485 ± 70 V isolated
Device connection 8-pol. plug connector for RS485
7-pol. plug connector for RS232
Operating temperature 0 – 60 °C, Optik 150 °C
Storage temperature -10 °C – 70 °C
Permissible humidity 35 – 85 % RF (non condensing)
Supply voltage 24 V DC ± 10 %
Power consumption < 100 mA
IP code IP65
Dimensions (LxHxW) / Weight 30 x 65 x 80 mm / 0,19 kg
Other Maximum memory, peak value memory double, adjustable time and threshold value, erasing after time, external contact, by software, after every measuring object

Fix-Focus

Fix-Fokus Optik Legend</strong
L Length of opics
C Distance from optics edge
M Measurement spot size
Optics C [mm] L [mm] Fiber [µm] M [mm]
VL 50-M12 50 38 200 0,7
400 1,4
600 2,0
VL 100-M12 100 40 200 1,0
400 2,0
600 3,0
VL 150-M12 150 38 200 1,4
400 2,7
600 4,0
VL 200-M12 200 38 200 2,0
400 4,0
600 6,0

Vario-Focus

Vario-Fokus Optik Legende</strong
L Length of optics
C Distance from optics edge
M Measurement spot size
Optics Cmin [mm] Cmax [mm] L [mm] Faser [µm] R Ratio
VL-VA N 65 160 46 – 56 200 138
400 69
600 46
VL-VA T 100 5000 46 – 56 200 150
400 75
600 50

QKTRD14xx for wave guide optics

KTRD14xx for wave guide optics

Optics for wave guides

optics for wave guides

Go to Top