Compact pyrometer – KTRD 4065

Measuring ranges from 100 °C to 1200 °C

1. 100 – 300 °C (D = 50)
2. 150 – 400 °C (D = 50)
3. 200 – 600 °C (D = 85)
4. 250 – 800 °C (D = 85)
5. 100 – 500 °C (D = 50)
6. 150 – 800 °C (D = 85)
7. 200 – 1200 °C (D = 85)

Special measuring ranges upon request

Categories: ,

Description

Performance, precision and reliability – you can count on MAURER pyrometers. The compact and easy to use design, as well as a large selection of matching accessories, enables you to quickly integrate the pyrometer into your surroundings.

The most important features and characteristics at a glance:

  • Spectral range: 2,1 μm
  • Short response time between 1 and 5 ms
  • Emissivity from 100 – 10 %, adjustable directly at the pyrometer or via interface
  • Green target light (LED) that is exactly identical to the actual measuring spot in position and size
  • With Vario-optic for exact focusing on the measuring spot
  • Use with either digital and analogue output
  • 1 limit output (open collector)
  • Operating voltage 24 V DC
  • Free software (IR-LOG) for parameter setting, data recording and storage

Scope of Applications
Processing of steel, iron, non-ferrous metal, wires and ceramics; rolling, soldering, welding, transforming, induction heating; vacuum furnace etc.

Configurations:

  • High speed version: KTRD 4065-HS
  • Special objectives and measuring ranges upon request
Spectral range 2,1 μm
Target marking Target light
Response time 1 – 5 ms, depending on measuring range
Measurement uncertainty 0,5 % ± 1 °C (ε = 1, Tu = 23°C, T 95 = 1s)
Temperature dependence 0,01 % / °C
Reproducibility 0,1 %
Emissivity 100 – 10 %, adjustable directly at the pyrometer or via interface
Resolution < 0,1 % at the analogue output < 0,1 °C at the interface
Analogue output 0 – 20 mA bzw. 4 – 20 mA (Load max. 500 Ω)
Limit output 1x 24 V 100 mA (open coll.)
Interface RS 232 ± 50 V isolated or RS 485 ± 70 V isolated
Device connection 8-pol. plug connector for RS485
7-pol. plug connector for RS232
Operating temperature 0 – 60 °C, Optik 150 °C
Storage temperature -10 °C – 70 °C
Permissible humidity 35 – 85 % RF (non condensing)
Supply voltage 24 V DC ± 10 %
Power consumption < 100 mA
IP code IP65
Dimensions (LxHxW) / Weight 30 x 65 x 80 mm / 0,19 kg
Other Maximum memory, peak value memory double, adjustable time and threshold value, erasing after time, external contact, by software, after every measuring object
Spektralbereich

2,1µm

Ansprechzeit

1 ms bis 5 ms, messbereichsabhängig

Messunsicherheit

0,5 % ± 1 °C (ε = 1, Tu = 23°C, T 95 = 1s)

Temperaturabhängigkeit

0,01 % / °C

KTRD4xxx with target light

KTRD40xx with targetlight

KTRD4xxx with viewfinder

KTRD40xx with viewfinder

Go to Top